All equipment
Edif1 / 3
Clinical Biochemistry Automated
Pulsar 250
Italian-made fully automatic clinical chemistry analyzer from Edif's PRO series, running up to 250 tests per hour. Refrigerated 36-bottle reagent rotor, 36 + 36 sample positions, barcode readers for samples and reagents as standard, 80 washable cuvettes and an optional ISE module.
- 250Tests per hour
- 36 + 36Sample positions
- 36Refrigerated reagent bottles
- 8Filters, 340–700 nm
Trade Price
On request
- Genuine Edif Product
- Maintenance by our engineers
- 24/7 technical support
- CE IVD
Product Details
- Up to 250 tests per hour
- Sample and reagent barcode readers as standard
- Refrigerated reagent and sample rotor
- Optional ISE module for electrolytes
- Capacitive liquid level detection and 3-axis needle shock sensor
- Automatic pre-dilution up to 1:100
- 80 washable cuvettes with 8-step washing
- Linear and non-linear calibration with up to 8 standards
- Three-level QC with lot monitoring
- Bi-directional LIS connection over Ethernet
- Made in Italy
Performance
- Throughput
- 250 tests/hour in single reagent mode
- Test types
- End point, bichromatic end point, differential end point, differential end point sample blank, fixed time, kinetic, kinetic bichromatic
- Test runs
- Random access with urgent (STAT) samples
- Precision
- Typical 2.0% CV for end point and kinetic
- Incubation + reading time
- Up to 800 seconds
- Electrolytes
- Optional ISE module
Sample & reagent handling
- Sample tray
- 36 + 36 positions: 12 – 13 mm barcoded tubes (5 – 7 mL) or 2 mL cups, free standard/control/urgent positions
- Reagent tray
- Removable rotor with 36 bottles of 50 or 20 mL (optional 38 or 15 mL), up to 1,440 mL total
- Refrigeration
- Reagents and samples cooled about 15 °C below room temperature
- Barcode
- Sample and reagent barcode readers as standard
- Pipetting volume
- Sample 1 – 255 µL, reagent 1 – 255 µL
- Pipetting precision
- 2% CV at 1 µL, 1.5% CV at 2 µL, 1% CV at 4 µL
- Sampling arm
- 1 needle, capacitive liquid level detection, 3-axis shock sensor
- Dilution
- In-needle dilution and automatic pre-dilution in a cuvette up to 1:100
Reaction system
- Cuvette rotor
- 80 washable direct-reading cuvettes, up to 30,000 tests per rotor
- Optical path
- 6 mm
- Reaction volume
- 100 – 500 µL
- Temperature
- Room temperature to 42 °C ± 0.2 °C
- Wash station
- 8-step washing sequence for each cuvette
Optics
- Light source
- Halogen lamp, 6 V / 10 W, extended UV emission
- Filters
- 340, 405, 505, 546, 578, 600, 650, 700 nm (10-position filter disk)
- Bandwidth
- ± 2 nm on peak, band pass ± 10 nm
- Photometric range
- 0 – 3 Abs
- Linearity
- ± 0.5% from 0.1 to 1.5 Abs
Calibration & QC
- Calibration
- 1 to 8 standards per test; linear (factor, linear, regression) and non-linear (cubic spline, polylinear, multi-parameter, logit-log 4P and 5P)
- Quality control
- 3 levels per test, one-month monitoring, reagent/calibrator/control lot tracking
Software & connectivity
- Methods
- Unlimited methods in memory, 100 active
- External PC
- Windows 10 or 11 via USB
- LIS
- Ethernet LAN, standard ASTM ASCII protocol
Power & physical
- Power supply
- 100 – 240 V AC, 50/60 Hz; under 200 VA (PC excluded)
- Water consumption
- Under 1 L/hour
- Dimensions
- 63 (W) × 77 (D) × 54 (H) cm
- Weight
- 47 kg
Talk to our team
Interested in the Pulsar 250?
Ask for a quote, delivery details or service options. Our team will get back to you quickly.