All equipment
Spinreact
Clinical Biochemistry Automated
Spin 800M
High-throughput, fully automatic clinical chemistry analyzer running 800 photometric tests per hour, up to 1,200 with the optional ISE module. 140 sample positions, a water-cooled 120-position reagent tray, intelligent clot and bubble detection, and a modular design that scales to the Spin 800 M1 and M2 systems.
- 1,200Tests per hour with ISE
- 140Sample positions
- 120Reagent positions, 2–8 °C
- 12Wavelengths, 340–800 nm
Trade Price
On request
- Genuine Spinreact Product
- Maintenance by our engineers
- 24/7 technical support
Product Details
- 800 tests per hour, up to 1,200 with the optional ISE module
- High sampling precision: 0.1 µL sample and 0.5 µL reagent steps
- Water-circulation reagent cooling keeps the tray at 2 – 8 °C
- Direct solid heating holds the reaction disk at 37 °C ± 0.1 °C
- Intelligent clot detection tells full jams, half jams and bubbles apart
- Reagent bubble and real liquid-level detection before aspiration
- Vertical and horizontal collision protection on all probes
- Independent mixers with three-head bars and two-stage washing
- Continuous reagent loading and unloading during testing
- Covered sample disk that can be partly opened when needed
- Waterproof cover over all electronics with drainage channel
- One-key STAT
- Built-in maintenance guide, warning log and water quality monitoring
- Modular: expands to Spin 800 M1 and M2 systems
Performance
- Throughput
- 800 tests/hour, up to 1,200 tests/hour with ISE
- ISE module (optional)
- Indirect Na⁺, K⁺, Cl⁻; 22 µL sample; up to 60,000 tests
- STAT
- One-key STAT
Sample handling
- Sample tray
- 140 positions, including 25 cooled positions for calibrators and controls
- Sample module
- 300 samples in 30 racks
- Sample volume
- 1.5 – 35 µL, in 0.1 µL steps
- Sample probe
- Liquid level detection, clot detection (full jam, half jam, bubbles), collision protection
Reagent handling
- Reagent tray
- 120 positions in coaxial disks, water-circulation cooling at 2 – 8 °C
- Reagent volume
- 15 – 300 µL, in 0.5 µL steps
- Reagent probe
- Liquid level detection, bubble detection, collision protection
- Loading
- Continuous loading and unloading during testing
Reaction system
- Reaction volume
- 100 – 360 µL
- Temperature
- 37 °C ± 0.1 °C, direct solid heating
- Mixing
- Independent reagent and sample mixers, three-head mixing bars, two-stage washing
Optics
- Light source
- Halogen-tungsten lamp, dot light source with dual diaphragm and dual lens
- Photometer
- Reversed optics, grating photometry
- Wavelengths
- 340, 380, 412, 450, 505, 546, 570, 605, 660, 700, 740, 800 nm
- Absorbance range
- 0 – 3.4 Abs (10 mm conversion)
Calibration & QC
- Calibration modes
- Linear (one-point, two-point, multipoint), Logit-Log 4P, Logit-Log 5P, spline, exponential, polynomial, parabola
- Control rules
- Westgard multi-rule, twin plot
Software
- Operating system
- Windows XP Professional/Home SP2 or later
- Maintenance
- Built-in maintenance guide, warning log, water quality monitoring
Modular system
- Spin 800
- 800/1,200 tests/hour, 140 samples, 68 reagents
- Spin 800 M1
- 800/1,200 tests/hour, 440 samples, 68 reagents
- Spin 800 M2
- 1,600/2,400 tests/hour, 580 samples, 136 reagents